Non-corneal Tonometry Glaucoma Eye Test Independent of Central Corneal Thickness (CCT) and Biometric Properties Featured at ESCRS, Paris France

 

 

Released on: September 24, 2010, 11:51 am
Author: : Alina Lagoviyer / BiCOM Inc. Public Relations
Industry: Healthcare

Unique non-corneal Tonometer Diaton, which allows to measure intraocular pressure (IOP) through the eyelid and sclera, unlike others that obtain IOP through cornea was featured at The European Society of Cataract and Refractive Surgeons ESCRS meeting in Paris, France.

Unique non-corneal Tonometer Diaton, which allows to measure intraocular pressure (IOP) through the eyelid and sclera, unlike others that obtain IOP through cornea was featured at The European Society of Cataract and Refractive Surgeons ESCRS.

Diaton tonometry is a unique approach of measuring intraocular pressure without touching the surface of the eye, takes tonometry reading over the upper eyelid and over the sclera. This revolutionary tonometry method allows physicians to obtain intraocular pressure without influence of central corneal thickness (CCT) and other known and unknown biometric properties and parameters of the cornea.

Unlike Goldmann tonometry which is based on the ImbertFick law and is effected by CCT and other corneal parameters and corneal diseases, where small area of the membrane is flattened to measure pressure of the internal fluid. Evidence shows that variations in CCT may greatly influence Goldmann tonometry reading. Parameters such as membrane elasticity, rigidity and other biomechanical properties can influence the accuracy of the intraocular pressure readings.

Diaton tonometry solves most of the corneal issues by implementing Newton 's Second Law and a Ballistic principle to obtain IOP. Readings with Diaton Tonometer are taken over the upper eyelid, at the tarsus and over the sclera, not the cornea.

Recent clinical study Comparison of Accuracy of Diaton Transpalpebral Tonometer Versus Goldmann Applanation Tonometer, Dynamic Contour Tonometer and Ocular Response Analyzer concluded: Transpalpebral Tonometry is an accurate method of IOP measurement that is also independent from the biomechanical characteristics of cornea. It can be recommended for IOP measurements of patients diagnosed with glaucoma including those cases where cornea pathology or cornea characteristics have been altered.

BiCOM Inc. ( New York , USA ) covers the full scope of customer service, which involves client training, follow ups, hotline support, sales support, etc. To get more information on the device or to make a purchase, visit the official website - http://www.TonometerDiaton.com, or call BiCOM at the toll free number 1-877-diatons (877-342-8667).

About BiCOM Inc.,
BiCOM, with its 19 years of tradition and global clientele, has proven to be the enterprise of the highest level of professionalism, integrity and financial solvency. A unique team of engineers, medical, legal and business experts makes BiCOM Inc. the right place for global talent to find support and guidance. BiCOM Inc. sees its mission in bringing to market innovative products developed and manufactured worldwide.

Diaton tonometer is presented in over 60 countries either direct by BiCOM Inc., or through Diaton tonometer distributors.

For more information or local distributors - please contact us through the website: http://www.TonometerDiaton.com

Press Contact -
Alina Lagoviyer / Media Relations
BiCOM Inc.
151 East Walnut Street
Long Beach , New York 11561
Phone: 1-877-342-8667 / Fax: 1-888-260-0606
Contact@TonometerDiaton.com
www.TonometerDiaton.com

 

WORD PDF PRINT

Back to previous page
Home page
Submit your press release